CTE Matched Thermal Management Materials Comparison
Compare the supplied grade-specific properties for CTE matched thermal management materials. Choose expansion, stiffness and conductivity together before defining your RFQ.
| Material grade | CTEppm/K | Thermal conductivityW/(m·K) | Young’s modulusGPa | Densityg/cm³ | Bending strengthMPa |
|---|---|---|---|---|---|
| AlSiC CTE6 | 5.5–6.5 | ≥170 | ≥230 | 3.04 ± 0.04 | >340 |
| AlSiC CTE7 | 6.5–8 | ≥180 | ≥220 | 2.98 ± 0.04 | >350 |
| AlSiC CTE8 | 7.5–9 | ≥180 | ≥200 | 2.96 ± 0.04 | >350 |
| AlSiC CTE10 | 9–11 | ≥180 | ≥190 | 2.93 ± 0.04 | >360 |
| AlSiC CTE10-T | 9–11 | ≥180 | 170–180 | 2.93 ± 0.04 | >360 |
| Low CTE AlSiC · TE3 | 3.5–4.5 | ≥180 | ≥330 | 3.03 ± 0.04 | >280 |
| AlSiC CTE14 | 13–15 | ≥185 | ≥130 | 2.88 ± 0.04 | >380 |
| Al-Diamond (8–10 grade) | 8–10 | >450 | >250 | 3.1–3.2 | — |
| Cu-Diamond | — | — | — | — | — |
1. AlSiC CTE values apply to 25–125°C. Al-Diamond CTE values apply to the selected 8–10 grade over 25–150°C; other test conditions are not specified in this table.
2. Cu-Diamond is offered as a portfolio option. Numerical properties require a part-specific specification. VC integration has no universal performance rating on this website.
3. Data is reproduced from the supplied material comparison, updated 17 November 2026. Values are not interpolated between grades and do not guarantee assembly-level performance.